July 19, 1994 No. 73

NDM Utility Patch

Several developers have reported difficulties accessing some of their data files using the NDM Revision 1.20 Utilities. The nature of this problem is that an "Error 123; Maximum conversion table entries are in use" error is displayed when using the "Access User Data" utility with some data files.

To correct this problem, the following program patches should be applied to the noted programs in the current NDMUTIL.BS2 diskimage.

  1. Program - START
    Line - 1000
    change
    GOSUB '31320(10,100,10,R0,R)
    to
    GOSUB '31320(10,@F0,10,R0,R)
  2. Program - ACCESS
    Line - 1000

    change
    DIM P8$200
    to
    DIM P8$@F0*2+50

As an alternative, an updated version of the NDMUTIL.BS2 file is available on the Niakwa Bulletin Board System in the Patches Conference. Refer to Tech Note #61 for a discussion of the Niakwa BBS system.

 